Input voltages (± 10%) CSA |
200 – 240 V, 1-PH, 50-60 Hz OR 480 V, 3-PH, 50-60 Hz1 |
Input current @ 6.5 kW CSA |
200 - 240 V, 1-PH, 39/32 A OR 480 V, 3-PH, 9.4 A1 |
Output current |
10–45 A |
Rated output voltage |
145 VDC |
Duty cycle @ 40° C (104° F) CSA |
50% @ 45 A, 200 – 240 V, 1-PH / 60% @ 41 A, 200 – 240 V, 1-PH /100% @ 32 A, 200 – 240 V, 1-PH / 50% @ 45 A, 480 V, 3-PH / 60% @ 41 A, 480 V, 3-PH / 100% @ 32 A, 480 V, 3-PH |
Open circuit voltage (OCV) |
275 VDC (200 - 240 V, CSA/CE/CCC and 480 V, CSA) / 265 VDC (400 V CE/CCC) |
Dimensions with handles |
442 mm (17.4") D; 173 mm (6.8") W; 357 mm (14.1") H |
Weight with 6.1 m (20') torch CSA |
14 kg (31 lbs.) |
Gas supply |
Cutting: air (clean, dry and oil-free), nitrogen, F5 / Gouging: air (clean, dry and oil-free), nitrogen, F5 / Marking: air (clean dry and oil-free) argon |
Recommended gas inlet flow rate / pressure |
188 I/min (400 scfh) @ 5,9 bar (90 psi) |
Input power cable length |
3 m (10') |
Power supply type |
Inverter – IGBT |
Engine drive requirement |
12.5 kVA (10 kW) for full 45 A output |
Electrical efficiency |
88% |
Recyclability |
100% |
Certifications |
CSA certified for use in the Americas and Asia, except China. |
Warranty |
Power supply: 3-year / Torch: 1-year |